In a RAID array I had a have periodically lost a drive here and there over the past several months. Iwas always able to readd and resync without losing data. However at some point it looks like some minor corruption happened and this makes DRBD unhappy.
Using fsck did not help either.
Dec 19 06:01:45 storageboxtest4 kernel: [19005.945890] EXT3-fs error (device drbd0): ext3_get_inode_loc: unable to read inode block - inode=22184379........
Before getting into the output here is my typical experience with SMART, there is what I call a "bad disk" with pending and uncorrectable sectors that cannot be reallocated.
It has caused a kernel panic and system crash repeatedly as we can see from the logs.
But SMART says it has "PASSED" its self assessment. SMART is still useful to me but it is more about looking at Current_Pending_Sector.
Any time I have had anything but 0 for that attribute it........
LSi Megaraid
At first it was configured as a RAID 0, then I deleted the Virtual Disk Group.
I thought both drives would be shown and detected in Linux as sda and sdb but it actually shows nothing.
To make them work you have to hit Ctrl+R before the system boots (when prompted) and create a Virtual Disk Group. In my case I created each one as RAID 0 (with a single drive only) as I just wanted JBOD but there is no such option or default in these Dell Pe........
Neither the blkid or the UUID internal to mdadm work to automount for some reason in Debian
partprobe doesn't work but was a good suggestion from: http://pato.dudits.net/2008/11/03/special-device-uuidxxxxxxxxxxxxxxxx-does-not-exist-especially-with-lvm
mount: special device /dev/disk/by-uuid/431b9b96-29e8f298-e89bd504-7065bddd does not exist
mdadm -D /dev/md_d12
mdadm: metadata format 00.90 unknown, ignored.
/dev/md_d12:
&nb........
I've only used it on Centos, soI thought I'd make a quick Debian guide:
Install the DRBD Package
apt-get install drbd8-utils
Reading package lists... Done
Building dependency tree
Reading state information... Done
The following packages were automatically installed and are no longer required:
libswfdec-0.8-0
Use 'apt-get autoremove' to remove them.
The following........
I separated the 2 drives in the RAID 1 array.
1 is the old one /dev/sda and is out of date, while the separated other one /dev/sdc was in another drive and mounted and used with more data (updated).
I wonder how mdadm will handle this:
usb-storage: device scan complete
md: md127 stopped.
md: bind
md: md127: raid array is not clean -- starting background reconstruction
raid1: raid set md127 active with 1 out of 2 m........