This is certainly a poor design, as you can read many seasoned admins who have updated their iDRAC only to have it killed. One possible cause is not by doing all the incremental updates, doing updates from an old iDRAC to one many revisions newer is a sure way to kill things, but even then there is no guarantee based on the amount of failures.
List of threads of people's dead iDRAC's:........
This guide assumes you have a working Postfix server and want it to sign with DKIM.
There are a few things we have to understand to make all of this work though, which require you to be familiar with DNS as well.
1.) Install OpenDKIM
apt install opendkim
systemctl enable opendkim
2.) Edit /etc/opendkim.conf
Syslog yes
SyslogSuccess yes
Mode&nbs........
convert-im6.q16: DistributedPixelCache '127.0.0.1' @ error/distribute-cache.c/ConnectPixelCacheServer/244.
convert-im6.q16: cache resources exhausted `/tmp/magick-27777Al6FGY7dhyKt10' @ error/cache.c/OpenPixelCache/3984.
convert-im6.q16: DistributedPixelCache '127.0.0.1' @ error/distribute-cache.c/ConnectPixelCacheServer/244.
convert-im6.q16: cache resources exhausted `/tmp/magick-277772Y_-pJnMdT2r1' @ error/cache.c/OpenPixelCache/3984.
convert-im6.q16: Distr........
Are you getting this error when trying to connect to a site/domain/service and then you checked your router/nameserver's logs to see what's wrong?
You may see something like this:
named[3025898]: REFUSED unexpected RCODE resolving
This is not usually an error with named or bind, at least not on your end but NORMALLY this is an issue with the remote nameserver.
A lot of times this is a misconfigured remote nameserver. A classi........
In today’s digital landscape, finding a reliable and secure Virtual Private Server (VPS) or Virtual Dedicated Server (VDS) goes beyond just comparing specs and prices. With increasing concerns over data privacy, security breaches, and government surveillance, the wisdom of choosing your VPS/VDS provider based on juri........
find /usr/share/zoneinfo/|sed s#"/usr/share/zoneinfo/"##g|grep "/"|grep -v posix|grep -v ^"Etc/"|grep -v ^right|grep -v ^"SystemV"
Africa/Addis_Ababa
Africa/Abidjan
Africa/Blantyre
Africa/Lusaka
Africa/Casablanca
Africa/Libreville
Africa/Asmara
Africa/Bujumbura
Africa/Dakar
Africa/Lagos
Africa/Malabo
Africa/Harare
Africa/Kigali........
If you are using a hypervisor to test Proxmox (eg. Vbox) then changing the video card/display adapter can fix it.
For example VboxSVGA causes the issue but switching to VMSVGA fixes it.
For example VboxSVGA causes the issue but switching to VMSVGA fixes it.
........
haproxy is one of the best known and widely used Open Source load balancers out there and a strong competitor to nginx.
haproxy is used by many large sites per Wikipedia:
HAProxy is used by a number of high-profile websites including GoDaddy, GitHub,........
The Best Docker Tutorial for Beginners
We quickly explain the basic Docker concepts and show you how to do the most common tasks from starting your first container, to making custom images, a Docker Swarm Cluster Tutorial, docker compose and Docker buildfiles.........
Have you been given a Zoom password that the meeting owner says is correct but it doesn't work anymore or never works?
If the meeting name says "Zoom Meeting" and it's not really named that (which most meetings are not), then the issue is usually that there is an initial password to be able to join, aside from the passcode. It basically means that Zoom has deauthenticated you randomly or maybe after X amount of uses, without clicking on the Join Meeting URL which contains a........
Why choose OpenVPN instead of a firewall appliance?
OpenVPN can be a reliable and easy replacement for traditional hardware or just be an additional tool that your company uses so that the firewall can focus on its job rather than acting as a VPNappliance at the same time.
When comparing OpenVPN with traditional firewal........
In our 2024 VPS Server/Cloud Buyer's Guide, we place the location of your VPS/hosting/server as one of the priorities that is often overlooked.
2024 Update - Datacent........
It is almost as intuitive as we would like it is just a *.
So literally:
*INA 127.0.0.1
Complete working bind zonefile below:
$TTL 86400
@ IN SOA ns.rtt.ca. ns2.rtt.ca. (
1247605715; Serial
&n........
The strange thing is that usually the first install or two will work on any new machine but then it suddenly won't. I had this experience on QEMU 2.13 on a different machine. There is something finicky or buggy about the CUCM installer even when choosing the same virtual hardware specs.
qemu-kvm command:
/usr/libexec/qemu-kvm -version
QEMU PC emulator version 0.12.1 (qemu-kvm-0.12.1.2-2.506.el6_10.1), Copyright (c) 2003-2008 Fabrice Bellard
........
Before getting into the output here is my typical experience with SMART, there is what I call a "bad disk" with pending and uncorrectable sectors that cannot be reallocated.
It has caused a kernel panic and system crash repeatedly as we can see from the logs.
But SMART says it has "PASSED" its self assessment. SMART is still useful to me but it is more about looking at Current_Pending_Sector.
Any time I have had anything but 0 for that attribute it........
[root@localhost:~]
BootModuleConfig.sh echo host-ind nfcd........
sudo apt-get install libcurl4-openssl-dev git build-essential autotools-dev autoconf libcurl3
sudo apt-get install libcurl4-gnutls-dev
git clone https://github.com/wolf9466/cpuminer-multi
sudo apt-get install cmake libpthread-* libmicrohttpd-dev libssl-dev libhwloc-dev
git clone https://github.com/fireice-uk/xmr-stak-cpu.git
make install
cd bin
chmod +x xmr-stak-cpu
./xmr-stak -O xmr........
Centos when copying old files and restarting it seems load everything fine and then says [FAILED] with no log or other message.
service restart named
named [FAILED]
Check more thoroughly you may have missed the error if you have lots of zones!
service named restart|grep error
zone 1.168.192.in-addr.arpa/IN: not loaded due to errors.
zone 2.168.192.in-addr.arpa/IN: no........
So you've got a responsive site with tables but it breaks them so anything not viewable on the screen is now cut off.
Here is a simple solution that will allow users to scroll horizontally so they can see the whole table:
&........
Intel NUC J3455 vs Vorke V1 J3160
Both are excellent units but the J3160 is nicer if you require even lower power usage (6W vs the Intel 10W). The price is attractive on the Vorke V1 as well. It's been said that the Intel J3455 NUC has a buggy BIOS and some other issues that require attention.
The Intel J3455 is still nice because it has 2 RAMslots but it does get hotter due to lack of fan.
The Vorke V1 runs cooler, uses less power an........
I believe from what I've read that this card's driver doesn't support the features after trying all known troubleshooting methods.
ffmpeg -i uservideoRendered.mp4 -filter:v hwupload_cuda,scale_npp=w=1920:h=1080:format=nv12:interp_algo=lanczos,hwdownload -c:v hevc_nvenc -profile main -preset slow -rc vbr_hq -c:a copy uservideoRendered.mp4-test
ffmpeg -i uservideoRendered.mp4 -filter:v hwupload_cuda,scale_npp=w=1920:h=1080:format=nv12:interp_algo=lanczos,hwdownload........
#if you have nvidia make sure you install the nvidia-cuda-toolkit so hardware acceleration can be used
wget http://ffmpeg.org/releases/ffmpeg-3.3.2.tar.bz2
tar -jxvf ffmpeg-3.3.2.tar.bz2
cd ffmpeg-3.3.2/
./configure --disable-yasm
install prefix /usr/local
source path ........
sudo mkdir -p /etc/X11/xorg.conf.d/
sudo vi /etc/X11/xorg.conf.d/20-intel.conf
On newer Ubuntu / Mint / Debian systems the file would go in: /usr/share/X11/xorg.conf.d/20-intel.conf
Type "i" and enter the following:
Section "Device"
Identifier "Intel Graphics"
Driver&n........
Finally after ages I found the solution which is on many pages on the net but not obvious and should have been standard or more common info!
Instant Solution:
Type this into the terminal (unfortunately the driver config menu doesn't have the option as itis hidden):
nvidia-settings --assign CurrentMetaMode="nvidia-auto-select +0+0 { ForceCompositionPipeline = On }"
Make permanent
Cli........
service named status
rndc: connect failed: 127.0.0.1#953: connection refused
named (pid 10557) is running...
This issue is normally caused by a permissions issue where named doesn't have the permissions to read the rndc.key.
Check /var/log/messages:
Jan 4 17:06:22 storagebox named[10753]: none:0: open: /etc/rndc.key: permission denied
Jan 4 17:06:22 storagebox named[10........
sudo apt-get install zoneminder
[sudo] password for one:
Reading package lists... Done
Building dependency tree
Reading state information... Done
The following packages were automatically installed and are no longer required:
libuser-perl python-evince kdebase-apps kwrite unixodbc
libgnomeprint2.2-data python-soappy vgabios python-metacity hddtemp
python-mediaprof........
i337 Canada on Bell is hard to root or even install TWRP
Installed TWRP from Odin and my computer gave me the bluescreen at the end but it seemed to be successful (after ODIN said reset).
TWRP mode does not seem to enter, instead you get the Android recovery mode with Volume up + Home
http://galaxys4root.com/galaxy-s4-root/how-to-root-att-or-verizon-galaxy-s4-on-android-4-4-2/
1.)........
https://www.2checkout.com/documentation/notifications/order-created
It shows all the parameters that get passed so you can make a simple script to process it.
To enable 2CONotifications you need to do the following:
Login
Browse to the top right to an icon that looks like a "circle with horizontal lines inside" - Notifications.
Enter the appropriate URL for your IPN/Notification processing script (........
This can happen when you install RPMForge or other repos with the wrong architecture and here's how you fix it (simply uninstalling won't usually fix it):
solution
yum clean all
yum -y install openvpn
Loaded plugins: fastestmirror, presto
Loading mirror speeds from cached hostfile
* base: mirror.its.sfu.ca
* extras: centos.mirror.nexicom.net
* rpmforge: mirror.cpsc.ucalgary.ca
* up........
zonetemplate=$(cat ........
Another new drive bad from the start:
Jun 2 15:14:18 one-desktop kernel: [15895.386779] ata2.00: exception Emask 0x50 SAct 0x1 SErr 0x280900 action 0x6 frozen
Jun 2 15:14:18 one-desktop kernel: [15895.386782] ata2.00: irq_stat 0x08000000, interface fatal error
Jun 2 15:14:18 one-desktop kernel: [15895.386784] ata2: SError: { UnrecovData HostInt 10B8B BadCRC }
Jun 2 15:14:18 one-desktop kernel: [15895.386788] ata2.00: cmd 60/0........
This is just trying to read 5GB off the drive with dd and the drive initially tested ok but shortly after I wondered why I was seeing 2MB/s read speeds. Notice the "current_pending_sector", anytime I've seen it at anything above 0 even with no other bad fields/attributes, it means the drive is bad.
ata1.00: exception Emask 0x0 SAct 0x3 SErr 0x0 action 0x0
ata1.00: irq_stat 0x40000008
ata1.00: failed command: READ FPDMA QUEUED
ata1.00: cmd 60/00:00:........
I dread updating the kernel and rebooting to find the Ubuntu graphics aren't working and you have to manually intervene. This is usually because Ubuntu for whatever reason didn't update the drivers you need (eg. the manually compiled Nvidia Kernel driver that MUST be recompiled for each and every kernel update unfortunately).
The most common reason may be that "linux-source" hasn't been installed automatically on my system. I tried to manually reinstall the........
I like dd, although it only reads it, usually a read test of the entire disk will uncover if your hard drive is bad in some parts. This is a good thing to do at least once a month, a lot of times bizarre program behavior, laginess and crashing/unnmounting problems etc.. are due to a failing disc and SMART won't know it or indicate a problem:
We must also remember there's never a guarantee, I've found that ever since we moved to larger and more platters per drive with 1TB drives........
I had a dying drive that smart thought until it totally disappeared was a good drive, and actually all parameters did look fine but this system was causing my system to lockup and other bad behavior:
=== START OF INFORMATION SECTION ===
Device Model: WDC WD20EARS-00MVWB0
Serial Number: WD-WMAZ20139
Firmware Version: 50.0AB50
User Capacity: 2,000,398,934,016 bytes
Device........
One thing to note about DNS servers and providers is that they aren't always trustworthy, not even if they're Google or your favorite ISP. Any DNS server can compromise your privacy, and they are likely tracking your browsing habits and keeping logs of it. Sometimes it's for Marketing/Research purposes such as Google's GMail service which they admit is scraped/datamined. I would expect nothing less from their DNS service.
The other danger with such widely used and pu........
I don't expect this to be solved soon but some of Yahoo's DNS servers are out of whack. I changed the IPs of some nameservers of some domains and now most Yahoo users can't e-mail to those domains!
As you can see below by the "No MX or A records for mychangedomain.com", now Yahoo's DNS/mailserver DNS cache is wrong. You would think they would at least have cached the old incorrect records, but instead for some reason their DNS cache has no entry and doesn't seem........
*Remember to restart spamassassin after all of this.
DCC
wget http://www.dcc-servers.net/dcc/source/dcc.tar.Z
tar -zxvf dcc.tar.Z
cd dcc-1.3.138/
./configure;make;make install
#enable DCC, uncomment the line that disables it near the top
vi /etc/mail/spamassassin/v310.pre
pyzor
wget http://sourceforge.net/projects/pyzor/files/pyzor/0.5.0/pyzor-0.5.0.tar.gz/down........
Centos 5 Postfix and SPAMASSASSIN Tutorial
yum install spamassassin
chkconfig spamassassin on
vi /etc/mail/spamassassin/local.cf
##############
#required_hits 5
#report_safe 0
#rewrite_header Subject [SPAM]
#5 is the least restrictive (means only the most obvious SPAM is caught. 0 is obviously the most restrictive/sensitive and would have lots of false positives
require........
genuine.com/IN: loading master file genuine.com.zone: file not found
_default/genuine.com/IN: file not found
I always found it silly that no one really talks about this and apparently many like me and even control panels like Plesk were still using hard paths. I always thought "why can't I just specify the name of the zone file and have bind find it". Surely the default search path must be /var/named or somewhere else but there is no such thing.........
Webmin/Virtualmin when enabling bind:
Failed to save enabled features : Virtualmin is configured to setup DNS zones, but this system is not setup to use itself as a DNS server. Either add 127.0.0.1 to the list of DNS servers, or turn off the BIND feature on the module config page.
It means what it says, add "127.0.0.1" to /etc/resolv.conf........
crontab not working
It is running as user Apache
I've tried 0 0 * * * (which means midnight 00:00) and it does run at midnight but also 13:25 for some reason?
25 0 * * * with this it runs at 00:25 but again also at 13:25
Solution - Restart the Cron Service (especially if you changed your time/timezone)
*Update I had a suspicion that changing the timezone a few weeks ago caused this. I restarted lhe cron service and the problem h........
Let the numbers speak for themselves, from what I read the Load_Cycle_Count which is very high (more than 500,000/half a million times) is the number of head parks. What a stupid"Green" design and design flaw which will probably mean an early life for the drive.
This is almost as silly as Seagate's new reputation for BSY/poor quality disks since the 7200.11 series.
To make it worse this is also when Western Digital introduced "Advanced Format" o........
This error is annoying, in a Virtuozzo KB entry about this ip tables nat problem they say the kernel needs to be ugpraded:
Symptoms
The node runs 2.6.18-x kernel older than 2.6.18-028stab053.10.
NAT module does not work in container, you get "can't initialize iptables table 'nat'" error:
# iptables -t nat........
cat /proc/user_beancounters produces the following:
kmemsize 1861537 5139870 12752512 12752512 26965041
Notice the failcnt "26965041", that is for kmemsize and at first it confused me. The system had enough guaranteed and enough burst RAM available. kmemsize is a variable indepedent of that, but who cars about the explanation right, let's just make thing........
PHP cannot access /usr/bin/opensslI have verified the username that runs the process is able to access /usr/bin/openssl and it does exist but the PHP script is saying it doesn't exist:
[code:1:1fd0f3abbe]
if (!file_exists($OPENSSL)) {
//echo "ERROR: OPENSSL $OPENSSL not foundn";
}[/code:1:1fd0f3abbe]
I don't get itI can clearly see the contents of /usr/bin by using the PHP system fu........
Photoshop Center A SelectionYou should have the item in it's own layer, select the layer and use CTRL+A to select the layer.
Then look for the alignment controls near the top of the screen (under the menus)
Use the Horizontal Center and Vertical Center and then your item will be perfectly centered.........
Intel's Finnish FetishIntel's Finnish Fetish
By Dave Mock
June 13, 2005
Chipmaker Intel (NASDAQ: INTC) has successfully topped the personal computer market for decades. Breaking into related areas such as communications has been much difficult for the world's largest semiconductor maker. But a new partnership with Nokia (NYSE: NOK) could help to change that.
Intel's forays into cellular-phone and home-entertaiment-device chips have........
Load Balancing/ClusteringAn interesting article that discusses the pros, cons and viability of load balancing/clustering
http://www.wwwcoder.com/main/parentid/493/site/4189/68/default.aspx
ZoneEdit seems to offer an interesting Fail Over Service as well:
http://www.zoneedit.com/doc/faq.html#fo........
In Newer Linux Distros This Way Is Easiest and works on newer versions like Ubuntu, Mint, Fedora, Centos, Debian etc.
#if you are missing timedatectl this in newer distros like Ubuntu/Mint/Debian and are using a container like Docker then do "apt install systemd"
timedatectl set-timezone America/Vancouver
Replace the America/Vancouver with the correct timezone.
To see the list you can just type "timedatectl set........
To enable Fuse to work inside a OpenVZ container it's very simple (although some people say it can't be done).
Remember that on your HN(HostNode) for OpenVZ, Fuse must be installed and the module must be loaded for this to work. In addition remember that you need the Fuse package installed inside the container of course.
vzctl set 2000 --devices c:10:229:rw --save
vzctl exec 2000 mknod /dev/fuse c 10 229
The part that most people forget........
I've had an old Blackberry for a few years and I was ready to spend some serious cash on a nice Nokia. I love the idea of the Linux based Symbian S60 OS, so I was looking at phones like the E63, E71 (both are basically the same, at least CPU/screensize although E71 is thinner, has a 3MP camera, has GPS, and has dedicated buttons to adjust the volume).
Then Iheard about the N97 and what a revolution it was supposed to be and it was even compared to iPhone.
To........
Feb 5 01:39:33 server named[19768]: zone myzone.com/IN: serial number (12331465) received from master 127.0.0.2#53 < ours (200901281)
The above is taken from /var/log/messages
This can be annoying, it can happen for a variety of reasons. What seems to be happening here is that the slave realizes the time on the slave is ahead of the master, so it therefore assumes it has the most up to date copy and won't actually transfer the zone.
The solutio........