Seagate 7200.11 firmware defect in 500GB, 1000GB (1TB) and 1500GB (1.5TB) Hard Drives

Seagate Inventory/Firmware Check

I heard about this issue a long time ago but never looked into it.  I figured I wasn't affected since my 500GB drives were running for so long.  I've been using Seagate's since 2002 and to this day all of the drives I have are alive from Seagate.

*Update the bad news is that I realize one of my 500GB's is about to die, it's not even a year old, but is also not affected by the recall according to Seagate!

Seagate Inventory/Firmware Check

=== START OF INFORMATION SECTION ===
Device Model:     ST3500820AS
Serial Number:    5QM05L23
Firmware Version: SD14
User Capacity:    500,107,862,016 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   7
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Tue Apr 20 04:59:22 2010 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                 ( 634) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 106) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   114   099   006    Pre-fail  Always       -       67367367
  3 Spin_Up_Time            0x0003   094   094   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       -       52
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       -       2
  7 Seek_Error_Rate         0x000f   068   051   030    Pre-fail  Always       -       81705593292
  9 Power_On_Hours          0x0032   077   077   000    Old_age   Always       -       20550
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   037   020    Old_age   Always       -       52
184 Unknown_Attribute       0x0032   100   100   099    Old_age   Always       -       0
187 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       0
188 Unknown_Attribute       0x0032   100   090   000    Old_age   Always       -       68
189 Unknown_Attribute       0x003a   097   097   000    Old_age   Always       -       3
190 Unknown_Attribute       0x0022   067   050   045    Old_age   Always       -       622460961
194 Temperature_Celsius     0x0022   033   050   000    Old_age   Always       -       33 (Lifetime Min/Max 0/21)
195 Hardware_ECC_Recovered  0x001a   054   026   000    Old_age   Always       -       67367367
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.


-----------

smartctl -a /dev/sdb
smartctl version 5.33 [x86_64-redhat-linux-gnu] Copyright (C) 2002-4 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Device Model:     ST3500320AS
Serial Number:    5QM0438P
Firmware Version: AD14
User Capacity:    500,107,862,016 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  Not recognized. Minor revision code: 0x29
Local Time is:    Tue Apr 20 05:00:12 2010 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                 ( 634) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 118) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   115   099   006    Pre-fail  Always       -       84286211
  3 Spin_Up_Time            0x0003   094   094   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       -       19
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       -       2
  7 Seek_Error_Rate         0x000f   069   060   030    Pre-fail  Always       -       30138716573
  9 Power_On_Hours          0x0032   078   078   000    Old_age   Always       -       19573
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       -       19
184 Unknown_Attribute       0x0032   100   100   099    Old_age   Always       -       0
187 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       0
188 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       0
189 Unknown_Attribute       0x003a   100   100   000    Old_age   Always       -       0
190 Unknown_Attribute       0x0022   067   048   045    Old_age   Always       -       639303713
194 Temperature_Celsius     0x0022   033   052   000    Old_age   Always       -       33 (Lifetime Min/Max 0/23)
195 Hardware_ECC_Recovered  0x001a   019   015   000    Old_age   Always       -       84286211
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

-------------------------

smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Barracuda 7200.11
Device Model:     ST3500320AS
Serial Number:    5QM3RH4S
Firmware Version: SD15
User Capacity:    500,107,862,016 bytes
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Tue Apr 20 20:13:11 2010 CST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                 ( 642) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 119) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x103b) SCT Status supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   103   097   006    Pre-fail  Always       -       47362968
  3 Spin_Up_Time            0x0003   095   094   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       -       34
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       -       8
  7 Seek_Error_Rate         0x000f   072   060   030    Pre-fail  Always       -       4310076883
  9 Power_On_Hours          0x0032   091   091   000    Old_age   Always       -       8272
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       1
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       -       34
184 Unknown_Attribute       0x0032   100   100   099    Old_age   Always       -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       -       0
188 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       0
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       -       0
190 Airflow_Temperature_Cel 0x0022   063   054   045    Old_age   Always       -       37 (Lifetime Min/Max 31/39)
194 Temperature_Celsius     0x0022   037   046   000    Old_age   Always       -       37 (0 22 0 0)
195 Hardware_ECC_Recovered  0x001a   022   022   000    Old_age   Always       -       47362968
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       1
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       1
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
----------------------

smartctl -a /dev/sda
smartctl version 5.38 [i686-redhat-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Device Model:     ST3500418AS
Serial Number:    6VM6QB1V
Firmware Version: CC37
User Capacity:    500,107,862,016 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Tue Apr 20 05:33:19 2010 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                 ( 592) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (  82) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x103f) SCT Status supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   119   100   006    Pre-fail  Always       -       218021758
  3 Spin_Up_Time            0x0003   097   097   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       -       37
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x000f   056   050   030    Pre-fail  Always       -       120273167939
  9 Power_On_Hours          0x0032   096   096   000    Old_age   Always       -       3718
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       -       18
183 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       0
184 Unknown_Attribute       0x0032   100   100   099    Old_age   Always       -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       -       0
188 Unknown_Attribute       0x0032   100   096   000    Old_age   Always       -       20
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       -       0
190 Airflow_Temperature_Cel 0x0022   075   065   045    Old_age   Always       -       25 (Lifetime Min/Max 22/28)
194 Temperature_Celsius     0x0022   025   040   000    Old_age   Always       -       25 (0 18 0 0)
195 Hardware_ECC_Recovered  0x001a   023   021   000    Old_age   Always       -       218021758
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0
240 Head_Flying_Hours       0x0000   100   253   000    Old_age   Offline      -       233946868616869
241 Unknown_Attribute       0x0000   100   253   000    Old_age   Offline      -       489393355
242 Unknown_Attribute       0x0000   100   253   000    Old_age   Offline      -       22729674

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

-------------------------------

smartctl -a /dev/sda
smartctl version 5.38 [i686-redhat-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Device Model:     ST3500418AS
Serial Number:    6VM6QB1V
Firmware Version: CC37
User Capacity:    500,107,862,016 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Tue Apr 20 05:33:19 2010 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                 ( 592) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (  82) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x103f) SCT Status supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   119   100   006    Pre-fail  Always       -       218021758
  3 Spin_Up_Time            0x0003   097   097   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       -       37
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x000f   056   050   030    Pre-fail  Always       -       120273167939
  9 Power_On_Hours          0x0032   096   096   000    Old_age   Always       -       3718
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       -       18
183 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       0
184 Unknown_Attribute       0x0032   100   100   099    Old_age   Always       -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       -       0
188 Unknown_Attribute       0x0032   100   096   000    Old_age   Always       -       20
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       -       0
190 Airflow_Temperature_Cel 0x0022   075   065   045    Old_age   Always       -       25 (Lifetime Min/Max 22/28)
194 Temperature_Celsius     0x0022   025   040   000    Old_age   Always       -       25 (0 18 0 0)
195 Hardware_ECC_Recovered  0x001a   023   021   000    Old_age   Always       -       218021758
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0
240 Head_Flying_Hours       0x0000   100   253   000    Old_age   Offline      -       233946868616869
241 Unknown_Attribute       0x0000   100   253   000    Old_age   Offline      -       489393355
242 Unknown_Attribute       0x0000   100   253   000    Old_age   Offline      -       22729674

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.




smartctl version 5.38 [i686-redhat-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Barracuda 7200.11
Device Model:     ST3500320AS
Serial Number:    5QM3LJXS
Firmware Version: SD15
User Capacity:    500,107,862,016 bytes
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Tue Apr 20 05:30:39 2010 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: FAILED!
Drive failure expected in less than 24 hours. SAVE ALL DATA.
See vendor-specific Attribute list for failed Attributes.

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                 ( 634) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 113) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x103b) SCT Status supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   114   100   006    Pre-fail  Always       -       73470535
  3 Spin_Up_Time            0x0003   094   094   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       -       51
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x000f   029   029   030    Pre-fail  Always   FAILING_NOW 62435953745688
  9 Power_On_Hours          0x0032   096   096   000    Old_age   Always       -       3736
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       1
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       -       51
184 Unknown_Attribute       0x0032   100   100   099    Old_age   Always       -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       -       0
188 Unknown_Attribute       0x0032   100   099   000    Old_age   Always       -       7
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       -       0
190 Airflow_Temperature_Cel 0x0022   074   062   045    Old_age   Always       -       26 (Lifetime Min/Max 21/29)
194 Temperature_Celsius     0x0022   026   040   000    Old_age   Always       -       26 (0 19 0 0)
195 Hardware_ECC_Recovered  0x001a   022   022   000    Old_age   Always       -       73470535
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

----------------------

smartctl version 5.38 [i686-redhat-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Device Model:     ST3500418AS
Serial Number:    6VM73A92
Firmware Version: CC37
User Capacity:    500,107,862,016 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Mon Apr 19 22:12:39 2010 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                 ( 592) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (  84) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x103f) SCT Status supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   114   100   006    Pre-fail  Always       -       61460953
  3 Spin_Up_Time            0x0003   097   097   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       -       34
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x000f   058   053   030    Pre-fail  Always       -       51549005329
  9 Power_On_Hours          0x0032   096   096   000    Old_age   Always       -       3723
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       -       17
183 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       0
184 Unknown_Attribute       0x0032   100   100   099    Old_age   Always       -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       -       0
188 Unknown_Attribute       0x0032   100   097   000    Old_age   Always       -       21
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       -       0
190 Airflow_Temperature_Cel 0x0022   076   061   045    Old_age   Always       -       24 (Lifetime Min/Max 21/27)
194 Temperature_Celsius     0x0022   024   040   000    Old_age   Always       -       24 (0 18 0 0)
195 Hardware_ECC_Recovered  0x001a   018   018   000    Old_age   Always       -       61460953
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0
240 Head_Flying_Hours       0x0000   100   253   000    Old_age   Offline      -       262547055840950
241 Unknown_Attribute       0x0000   100   253   000    Old_age   Offline      -       550274327
242 Unknown_Attribute       0x0000   100   253   000    Old_age   Offline      -       11295433

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
=======================
1TB drives

Device: ATA      ST31000520AS     Version: CC32
Serial number:             6VX0DJGE
Device type: disk
Local Time is: Mon Apr 19 21:10:57 2010 PDT
Device does not support SMART

Error Counter logging not supported

[GLTSD (Global Logging Target Save Disable) set. Enable Save with '-S on']
Device does not support Self Test logging
-bash-3.1# smartctl -a /dev/sdb
smartctl version 5.36 [i686-pc-linux-gnu] Copyright (C) 2002-6 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

Device: ATA      ST31000520AS     Version: CC32
Serial number:             6VX0DYCN
Device type: disk
Local Time is: Mon Apr 19 21:11:05 2010 PDT
Device does not support SMART

Error Counter logging not supported

[GLTSD (Global Logging Target Save Disable) set. Enable Save with '-S on']
Device does not support Self Test logging
-bash-3.1# smartctl -a /dev/sddsmartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Barracuda 7200.11
Device Model:     ST31000340AS
Serial Number:    6QJ02P1E
Firmware Version: SD15
User Capacity:    1,000,204,886,016 bytes
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Tue Apr 20 05:06:45 2010 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                 ( 642) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 233) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x103b) SCT Status supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   117   099   006    Pre-fail  Always       -       146967665
  3 Spin_Up_Time            0x0003   098   098   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       -       2
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       -       87
  7 Seek_Error_Rate         0x000f   080   060   030    Pre-fail  Always       -       4401858806
  9 Power_On_Hours          0x0032   090   090   000    Old_age   Always       -       9062
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       -       13
184 Unknown_Attribute       0x0032   100   100   099    Old_age   Always       -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       -       0
188 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -       8
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       -       0
190 Airflow_Temperature_Cel 0x0022   059   049   045    Old_age   Always       -       41 (Lifetime Min/Max 35/46)
194 Temperature_Celsius     0x0022   041   051   000    Old_age   Always       -       41 (0 35 0 0)
195 Hardware_ECC_Recovered  0x001a   033   015   000    Old_age   Always       -       146967665
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
smartctl version 5.36 [i686-pc-linux-gnu] Copyright (C) 2002-6 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

Device: ATA      ST31000333AS     Version: CC1F
Serial number:             9TE0840X
Device type: disk
Local Time is: Mon Apr 19 21:11:07 2010 PDT
Device does not support SMART

Error Counter logging not supported

[GLTSD (Global Logging Target Save Disable) set. Enable Save with '-S on']
Device does not support Self Test logging

-----------------------------

You can use Seagate's tool to check if your serial number is affected.  My drives have been working for as long as 4 years now so I don't think they are affected.

http://seagate.custkb.com/seagate/crm/selfservice/search.jsp?DocId=207931

Results of any of the 7200.11 (the ones I read have the defect):
It's

SNo      Serial number      Result      Action
1     6QJ02P1E     No download available for this serial number.     No action required.
2     5QM3RH4S     No download available for this serial number.     No action required.
3     5QM3LJXS     No download available for this serial number.     No action required.
4     9TE0840X     No download available for this serial number.     No action required.
5     6VX0DYCN     No download available for this serial number.     No action required.
6     6VX0DJGE     No download available for this serial number.     No action required.
              &


Tags:

seagate, firmware, defect, gb, tb, drivesseagate, inventory, wasn, ve, update, qm, user, capacity, bytes, smartctl, database, showall, ata, specification, draft, indicated, tue, apr, pdt, capability, enabled, overall, assessment, offline, completed, auto, execution, previous, capabilities, execute, suspend, scan, supported, conveyance, selective, saves, mode, supports, timer, logging, recommended, polling, extended, attributes, revision, vendor, thresholds, attribute_name, thresh, updated, when_failed, raw_value, raw_read_error_rate, spin_up_time, start_stop_count, old_age, reallocated_sector_ct, seek_error_rate, power_on_hours, spin_retry_count, power_cycle_count, unknown_attribute, temperature_celsius, min, hardware_ecc_recovered, current_pending_sector, offline_uncorrectable, udma_crc_error_count, errors, logged, span, min_lba, max_lba, current_test_status, not_testing, flags, scanning, selected, spans, remainder, disk, pending, resume, dev, sdb, _, redhat, linux, gnu, copyright, allen, http, smartmontools, sourceforge, pc, barracuda, rh, acs, cst, sct, feature, reported_uncorrect, high_fly_writes, airflow_temperature_cel, sda, vm, qb, cc, head_flying_hours, ljxs, attribute, failing_now, vx, djge, gltsd, global, disable, enable, bash, dycn, sddsmartctl, qj, te, custkb, crm, selfservice, jsp, docid, sno, download,

Latest Articles

  • FreePBX 17 How To Add a Trunk
  • Docker Container Onboot Policy - How to make sure a container is always running
  • FreePBX 17 How To Add Phones / Extensions and Register
  • Warning: The driver descriptor says the physical block size is 2048 bytes, but Linux says it is 512 bytes. solution
  • Cisco How To Use a Third Party SIP Phone (eg. Avaya, 3CX)
  • Cisco Unified Communication Manager (CUCM) - How To Add Phones
  • pptp / pptpd not working in DD-WRT iptables / router
  • systemd-journald high memory usage solution
  • How to Install FreePBX 17 in Linux Debian Ubuntu Mint Guide
  • How To Install Cisco's CUCM (Cisco Unified Communication Manager) 12 Guide
  • Linux Ubuntu Redhat How To Extract Images from PDF
  • Linux and Windows Dual Boot Issue NIC Won't work After Booting Windows
  • Cisco CME How To Enable ACD hunt groups
  • How to install gns3 on Linux Ubuntu Mint
  • How to convert audio for Asterisk .wav format
  • Using Cisco CME Router with Asterisk as a dial-peer
  • Cisco CME How To Configure SIP Trunk VOIP
  • Virtualbox host Only Network Error Failed to save host network interface parameter - Cannot change gateway IP of host only network
  • Cisco CME and C7200 Router Testing and Learning Environment on Ubuntu 20+ Setup Tutorial Guide
  • Abusive IP ranges blacklist